CRT 48 Maintenance
wc_tx000642gb.fm 39
5.12 Servicing the Air Cleaner
See Graphic: wc_gr003776
5.12.1 Unlock clamps (a) and remove cover (b).
5.12.2 Remove cartridge (c) from air cleaner body.
The filter can be cleaned by blowing compressed air breadthways
outside and inside the cartridge, at a pressure not greater than 4.9 bar
(70 psi), or by knocking the front of the filter several times against a flat
surface. Replace filter if it appears heavily soiled or damaged.
5.12.3 Carefully clean out air cleaner cover.
NEVER use gasoline or other types of low flash point solvents for
cleaning the air cleaner. A fire or explosion could result.
5.12.4 Install filter in body.
5.12.5 Install cover and lock clamps.
NOTICE: NEVER run engine without air cleaner. Severe engine
damage will occur.
WARNING