Wacker Neuson WL 30 Manual del operador Pagina 80

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 246
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 79
O P E R ATI NG A N D O P E R AT I O N
78
5.2.6 Starting the engine
Due to the high viscosity in the hydraulic sys-
tem at temperatures below 0°C (32°F), major
machine damage can occur when the speed is
increased immediately.
Let the engine run at a low speed at tempera-
tures below 0°C (32°F) until the hydraulic uid
is warm enough to permit smooth responsive
operation.
The lower the outside temperature, the longer
the warm-up phase.
Observe the hydrolter‘s pressure display.
Do not under any circumstances tow-start the
loader to start the engine. This could damage
the hydraulic system.
Turn off the engine immediately if the warning
lights do not go out when the engine is running.
Have the malfunction rectied immediately. Do
not use the loader again until the malfunction
has been rectied.
Do not suddenly turn off the engine from full
load, but rather allow it to idle for 3 minutes be-
fore turning it off it to equalize the temperature.
Check that no one is in the loader‘s danger area.
Do not use ether as a starting aid.
Do not use the loader if the »starter inhibitor«
does not function.
Only start the loader from the operators seat.
Fig. 30
Starting switch
I
0
II
Vista de pagina 79