Technical data EHB 11
Extension cable for the US market:
Example
You utilize an EHB 11 BLM/230 and want to use an extension cable with a length
of 50 m (164 ft).
The machine has an input voltage of 230 V.
According to the table, the extension cable must feature a cross-section area of
4.0 mm
2
(AWG 12).
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
110–130 < 36 14
< 58 12
< 89 10
220–240 < 75 16
< 121 14
< 190 12
< 302 10