Maintenance GP/GPS 6600A
wc_tx000799gb.fm 38
4.6 Cleaning the Sediment Cup
4.6.1 Turn the fuel valve off.
4.6.2 Remove the sediment cup (a) and the O-ring (b).
4.6.3 Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
4.6.4 Turn the fuel valve on and check for leaks.
wc_gr000029
b
a