www.wackergroup.comGeneratorGP 2500AOPERATOR’S MANUAL0160531en 00211060160531EN
Safety Information GP 2500Awc_si000149gb.fm 83.2.12 ALWAYS store the equipment properly when it is not being used.Equipment should be stored in a clea
GP 2500A Safety Informationwc_si000149gb.fm 93.3 Operator Safety while using Internal Combustion EnginesInternal combustion engines present special ha
Safety Information GP 2500Awc_si000149gb.fm 103.4 Service SafetyPoorly maintained equipment can become a safety hazard! In orderfor the equipment to
GP 2500A Safety Informationwc_si000149gb.fm 113.5 Label Locations GND88897
Safety Information GP 2500Awc_si000149gb.fm 123.6 Safety and Operating LabelsWacker machines use international pictorial labels where needed.These lab
GP 2500A Safety Informationwc_si000149gb.fm 13Electrical groundCAUTION! Use only clean, filtered gasoline fuel.Check the fuel level.Open the fuel flow
Safety Information GP 2500Awc_si000149gb.fm 14Pull the rewind starter.Open the choke.Turn the engine switch to "OFF".Close the fuel flow val
GP 2500A Technical Datawc_td000149gb.fm 154. Technical Data4.1 GeneratorItem No. GP 2500A0620009GeneratorMaximum OutputW2500Continuous OutputW2250Type
Technical Data GP 2500Awc_td000149gb.fm 164.2 EngineItem No. GP 2500A0620009EngineEngine Make HondaEngine Model GX 160 K1VXRated PowerkW (Hp)4.1 (5.5)
GP 2500A Operationwc_tx000447gb.fm 175. Operation5.1 Determining Power RequirementsThis generator is designed to operate single-phase, 60 Hz appliance
DANGERCARBON MONOXIDEUsing a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon
Operation GP 2500Awc_tx000447gb.fm 185.2 Outdoor InstallationPlace the generator in an area where it will not be exposed to rain,snow, or direct sunli
GP 2500A Operationwc_tx000447gb.fm 195.4 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combustion eng
Operation GP 2500Awc_tx000447gb.fm 205.5 Grounding the GeneratorSee Graphic: wc_gr000544A ground connection (a) is located on the generator frame. For
GP 2500A Operationwc_tx000447gb.fm 215.7 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generator, a v
Operation GP 2500Awc_tx000447gb.fm 225.8 Control Panel—GP 2500ASee Graphic: wc_gr002324Ref. Description Ref. Descriptiona GFI duplex receptacle—120V d
GP 2500A Operationwc_tx000447gb.fm 235.9 Ground Fault Interrupt (GFI)See Graphic: wc_gr002324The 120V, 20 Amp receptacle (a) is equipped with a ground
Operation GP 2500Awc_tx000447gb.fm 245.11 Before Starting5.11.1 Read and understand the safety and operating labels and instructionsat the beginning o
GP 2500A Operationwc_tx000447gb.fm 255.12 To StartSee Graphic: wc_gr0028185.12.1 Disconnect all loads from the generator.5.12.2 Open the fuel valve (a
Maintenance GP 2500Awc_tx000448gb.fm 266. Maintenance6.1 Engine MaintenanceThe chart below lists basic machine and engine maintenance. Refer tothe eng
GP 2500A Maintenancewc_tx000448gb.fm 276.3 Engine OilSee Graphic: wc_gr0000226.3.1 Drain the oil while the engine is still warm.6.3.2 Remove the oil f
GP 2500A Table of Contentswc_bo0160531en_002TOC.fm 11. Foreword 32. California Evaporative Emission Control Warranty Statement 43. Safety Information
Maintenance GP 2500Awc_tx000448gb.fm 286.4 Servicing Air CleanerSee Graphic: wc_gr002815Service the air cleaner frequently to prevent carburetor malfu
GP 2500A Maintenancewc_tx000448gb.fm 296.5 Spark PlugSee Graphic: wc_gr000028Clean or replace the spark plug as needed to ensure proper operation.Refe
Maintenance GP 2500Awc_tx000448gb.fm 306.6 Cleaning the Sediment CupSee Graphic: wc_gr0000296.6.1 Turn the fuel valve off. 6.6.2 Remove the sediment c
GP 2500A Maintenancewc_tx000448gb.fm 316.7 Carburetor AdjustmentSee Graphic: wc_gr0000326.7.1 Start the engine and allow it to warm up to operating te
Maintenance GP 2500Awc_tx000448gb.fm 326.8 Adjusting Engine SpeedSee Graphic: wc_gr000032Generators require a fixed engine speed to maintain the corre
GP 2500A Maintenancewc_tx000448gb.fm 336.10 Transport Let the engine cool before transporting the generator or storingindoors, to avoid burns or fire
Maintenance GP 2500Awc_tx000448gb.fm 346.12 Wire Colors6.13 Wiring SchematicSee Graphic: wc_gr002325 Wire ColorsB Black R Red Y Yellow Or OrangeG G
GP 2500A Maintenancewc_tx000448gb.fm 35
Maintenance GP 2500Awc_tx000448gb.fm 36Notes
Table of Contents GP 2500Awc_bo0160531en_002TOC.fm 26. Maintenance 266.1 Engine Maintenance ...
Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax:
wc_tx000001gb.fm 3CALIFORNIAProposition 65 Warning: Engine exhaust, some of its constituents, and certain vehiclecomponents, contain or emit chemical
California Evaporative Emission Control Warranty Statementwc_tx000572gb.fm 42. California Evaporative Emission Control Warranty StatementYOUR WARRANT
California Evaporative Emission Control Warranty Statementwc_tx000572gb.fm 5OWNER’S WARRANTY RESPONSIBILITIES:As the portable generator owner, you are
Safety Information GP 2500Awc_si000149gb.fm 63. Safety InformationThis manual contains DANGER, WARNING, CAUTION, and NOTEcallouts which must be follow
GP 2500A Safety Informationwc_si000149gb.fm 73.2 Operating SafetyBACKFEED FROM THE GENERATOR INTO THE PUBLIC POWERDISTRIBUTION SYSTEM CAN CAUSE SERIOU