GV 7000A / 7003A Operation
wc_tx001624gb.fm 31
4.11 Stopping
See Graphic: wc_gr001299
4.11.1 Turn off and disconnect all tools and appliances attached to the
generator.
4.11.2 Turn engine switch to “OFF” (c2).
4.11.3 Close fuel valve (a).
Note: To stop engine quickly in an emergency, turn engine switch to
“OFF” (c2).
4.12 Emergency Shutdown Procedure
Procedure
If a breakdown or accident occurs while the machine is operating,
follow the procedure below:
4.12.1 Stop the engine.
4.12.2 Turn off the fuel supply.
4.12.3 Disconnect tools from the machine.
4.12.4 Allow the machine to cool.
4.12.5 Contact the rental yard or machine owner for further instructions.