Maintenance PT 2 / PT 2A / PT 2H
46 wc_tx001838gb.fm
5.14 Cleaning the Pump
See Graphic: wc_gr000036
Clean inside of pump housing after every use.
5.14.1 Remove drain plug (a) from pump housing and drain any water left in
pump.
5.14.2 Loosen the four knobs holding the pump cover (b) and remove cover.
5.14.3 Clean out dirt and debris. Inspect impeller and volute insert for wear.
The impeller may develop sharp edges. Use care when cleaning
around impeller to avoid getting cut.
WARNING